NovaUPpro Consulting
TransformersData Center SolutionsAbout
ENTRITRU
RFQ
Data Center Solutions

Full power scope for AI campuses.

Hyperscale, colocation or enterprise — one engineered scope from the utility incomer to the last PDU, with uptime math to back every rating.

Scope my projectExplore scope
AI Infrastructure Matrix
Tier III / IV
One partner for grid connection to hall distribution
N / N+1 / 2N redundancy engineered per hall
Losses guaranteed in writing — PUE you can plan on
Typical first quote in 48 hours from a load list — full engineered proposal in 2 weeks.
Availability Target
0% SLA
Grid Feed Arch
2N Synchronous
Scope areas

Six areas, one accountable partner.

Grid Connection & Primary Substations

10–120 MVA power transformers stepping utility voltage down to your medium-voltage ring — with impedance matched to fault levels.

  • Up to 170 kV class
  • OLTC for voltage regulation
  • Fault-level coordination

Hall Distribution

500–5000 kVA units feeding UPS halls, busbar and PDUs — K-factor rated for GPU harmonic spectra.

  • K-13 / K-20 windings
  • Low-noise dry-type options
  • Busbar-ready LV terminals

AI Load Engineering

We model inrush, harmonics and step-loads of your GPU clusters so the transformer never becomes the bottleneck.

  • Load-profile sizing
  • Harmonic analysis
  • Overload headroom 20–30%

Efficiency & PUE Optimization

Amorphous-core and low-loss designs that shave real MWh off 24/7 operation — with capitalized-loss comparisons.

  • ≤ 0.6% total losses
  • Total-owning-cost quotes
  • Temperature-rise guarantees

Uptime & Redundancy Design

Failure-mode planning per hall: what happens when one unit trips, and how fast the spare picks up.

  • N+1 / 2N layouts
  • Parallel-operation setup
  • Protection coordination

Fast-Track Delivery & Commissioning

Reserved factory slots, export packing and supervised installation — energized in 8–12 weeks on standard ratings.

  • FAT with full protocol
  • Site supervision
  • SAT & energizing support
How we work

From first call to energized hall.

01

Site & load intake

We review your single-line diagram, IT MW per hall and PUE target — on a call or on site with your EPC.

02

Rating & redundancy proposal

You get a rated proposal: MVA, impedance, cooling, losses and redundancy layout — priced with lead time.

03

Build, test & witness

Manufacturing with stage photos, then FAT you can attend in person or remotely with live test data.

04

Deliver & energize

Transport, installation supervision and step-by-step energizing until the hall runs on the new units.

Start scoping

Tell us your MW — we handle the rest.

A 30-minute scoping call is enough to map grid connection, hall distribution and redundancy for a first proposal.

[email protected]+90 (000) 000 00 00

Bring your EPC if you like — we speak single-line diagrams, fault levels and test protocols fluently.

Scope my projectSee transformers
NovaUPpro Consulting

High-efficiency transformers for AI data centers. Tier-ready, low-loss, fast-track delivery.

Compliance

IEC 60076 · IEEE C57 · ISO 9001 FAT-tested before shipment.

ENTRITRU

Contact

  • [email protected]
  • +90 (000) 000 00 00
  • Istanbul / Ankara — serving EMEA

Quick Links

  • Home
  • Transformers
  • Data Center Solutions
  • Request a Quote
  • About

Stay Updated

Lead times, new ratings, AI load guides. No spam.

© 2026 NovaUp Pro. All rights reserved. (Demo mockup)

ImprintPrivacy